Gregoriou Brothers Refrigeration Since 1979. 410A, R410a, Refrigerant Recharge Servie Kit Gauge, Hose, Instructions Vac-Pump. We are a Certified UPS Haz Mat Shipper. This kit is for Recharging Refrigerant R-410a Systems.

Refrigerant R410a is used on almost all "NEW" A/C Units and almost all of the "mini-split" A/C systems. As R-22 is being phased out, R-410a is now the refrigerant found on all "NEW" A/C Systems. Can of R-410a with a 1/4 male flare fitting on top with internal valve core and brass cap as pictured. (1) Reusable , Quick Connect (screw-on), Top Mount Can Taper with color coded charging gauge for R410a systems.

(1) SPECIAL, R410a, COLOR CODED, "CHECK & CHARGE-IT" Gauge. (1) CPS AD87 R410a adapter Fitting. (1) Model# 4015, Pittstop Pro Series Vacuum Pump 2.6 CFM. This professional refrigeration and air conditioning system, 2.6 CFM vacuum pump, is used to evacuate any air and non-condensibles from the system prior to charging the system with refrigerant.

The vacuum pump is not intended to recover the refrigerant from a system, that would be a "refrigerant recovery unit". The vacuum pump is used only AFTER the A/C system is empty of refrigerant or on a new installation and is used to pull a vauum on the system to remove air and all non-condensibles prior to charging with refrigerant.

This professional vacuum pump will work with R12, R22, R134a, R410, 404, 407, 409, 502, A/C & Refrigeration systems. Air Conditioning (including automotive applications). Good for up to 29 At Sea Level. INTAKE FITTING: 1/4" R12 systems or 1/2" ACME R134a systems. Oil sight glass for monitoring oil levels.

Normal R410a low-side system pressure while unit is running is; 120 to 150 psi. Depending on the outdoor and indoor temperature. Some R410a systems still use the 1/4 male flare so in this case the charging hose with this kit will connect directly onto it. The charging hose on this kit has the larger 5/16 connection with valve core depressor. You will need this special hose because the new size found on almost all mini-splits and some R410a A/C systems is now larger (5/16) to prevent mixing, so now you will have everything you need to recharge a R410a system. FOR USE BY QUALIFIED Refrigeration and Air Conditioning TECHNICIANS. USE ONLY IN AIR CONDITIONING SYSTEMS DESIGNED FOR R410A. DO NOT MIX WITH ANY OTHER REFRIGERANT. ALWAYS WEAR EYE PROTECTION WHEN WORKING WITH REFRIGERANTS. ALWAYS WEAR GLOVES WHEN WORKING WITH REFRIGERANTS.

VAPOR HARMFUL SKIN AND EYE IRRITANT. DO NOT CONNECT THIS CAN TO THE HIGH PRESSURE SIDE OF THE SYSTEM, THIS MAY CAUSE THE CAN OR CONTAINER TO. BURST AND RESULT IN SERIOUS INJURY.

ALWAYS REPAIR LEAKS BEFORE ADDING REFRIGERANT. USE ONLY IN SYSTEMS DESIGNED FOR REFRIGERANT R410A. FOR LOW PRESSURE SIDE OF THE SYSTEM ONLY!!! DO NOT EXPOSE THIS CAN TO HEAT OR STORE IN TEMPERATURES ABOVE 120 F.

HIGH TEMPERATURES MAY CAUSE THE CAN TO BURST. DO NOT PUNCTURE OR INCINERATE THIS CAN. DO NOT STORE IN PARKED VEHICLES WHERE THE INSIDE TEMPERATURE MAY EXCEED 120 F. KEEP OUT OF REACH OF CHILDREN. If you are purchasing this item for resale only to EPA Certified Technicians then please indicate so in a message and please keep accurate records of same.

Certified Hazardous Material Shipper for both the United States and Canada. This recharge kit includes; (1) 28 oz. (1) Reusable, Quick Connect (screw-on), Top Mount Can Taper with color coded charging gauge for R410a systems. (1) CPS AD87 R410a adapter Fitting (1) 36 Charging Hose Instructions on R410a systems.

--(1) Model# 4015, Pittstop Pro Series Vacuum Pump 2.6 CFM --- This professional refrigeration and air conditioning system, 2.6 CFM vacuum pump, is used to evacuate any air and non-condensibles from the system prior to charging the system with refrigerant. FEATURES: ------Rotary ------High Efficiency ------Low Noise ------Preventing Oil Return ------Perfect Appearance ------Good for up to 29 At Sea Level ------120 watt motor ------RPM: 1720 ------Voltage: 110 V, 60HZ. Or 6.9 (kg) INTAKE FITTING: 1/4" R12 systems or 1/2" ACME R134a systems.

-----Oil Drain Plug ------Inlet fittings for R12/R134a ------On/Off Switch ------Line cord 110 vac Normal R410a low-side system pressure while unit is running is; 120 to 150 psi. Refrigerant Can Notes WARNING ALWAYS WEAR EYE PROTECTION WHEN WORKING WITH REFRIGERANTS.

DO NOT CONNECT THIS CAN TO THE HIGH PRESSURE SIDE OF THE SYSTEM, THIS MAY CAUSE THE CAN OR CONTAINER TO BURST AND RESULT IN SERIOUS INJURY. FOR LOW PRESSURE SIDE OF THE SYSTEM ONLY!!!! This item is in the category "Business & Industrial\HVAC & Refrigeration\HVAC & Refrigeration Tools\HVAC & Refrigeration: Gauges & Probes". The seller is "john102561" and is located in this country: US.